I recently installed uninstalled my previous version of LIMS-plus 3.62.13 and installed v3.7.19.  Launching the application produces the following error message.

2005 – Error Loading file – record number 14. frsMainCaseview <or one of its members>.  Parent: Type

Conversion required by the DataType property for field ‘NextChildNum’ is invalid

 

Description:

NextChildNum_Launch.JPG

 

Root Cause:

The database being connected has an incorrect data type property value on the field 'NextChildNum' located on the request table.

 

Solution:

Check the requests table and make sure the the field in question (NextChildNum) is set with a data type of (int(not null).  

NextChildNum_Table.JPG

Expand requests, NextChildNum will be the last field listed.

NextChildNum_Field.JPG

Make sure this field is set to int data type.

If the field is set to another data type (ex varchar,200), the error message will occur.

 